Emc cli commands

Over the years the CLI has evolved into a secure interface known as naviseccli and provides the same functionality as the Navisphere Manager graphical user interface. The classic navicli interface provides basic storage configuration and management commands. The CLI interface communicates directly with the SP Agent over port and has built-in authorization and authentication security mechanisms.

Note: For security and auditing reasons it makes sense to use "naviseccli" over the classic navicli where possible. Customer may choose to use the alternate port of for secure communication The actual port used is determined during storage-system initialization.

Please note that this document is a translation from English, and may have been machine-translated. It is possible that updates have been made to the original version after this document was translated and published. Veritas does not guarantee the accuracy regarding the completeness of the translation. You may also refer to the English Version of this knowledge base article for up-to-date information. Support Knowledge base Article: Last Published: Ratings: 4 3.

Secure CLI requires either port or to be opened for proper operation. Was this content helpful?

Openstack basic CLI command Configuration

Yes No Rating submitted. Please provide additional feedback optional :. Cancel Submit. You are using Microsoft Internet Explorer!

Microsoft no longer supports this browser. As a result, some of the functionality on this website may not work for you.

For an optimal experience on our website, please consider changing to Microsoft Edge, Firefox, Chrome or Safari. Article Languages. Translated Content Please note that this document is a translation from English, and may have been machine-translated.EMC Global Services. Cloud Tiering Appliance. Data Protection Advisor. Infrastructure Connectivity. You can access the command-line interface by opening a secure shell SSH connection to any node in the cluster.

You can run isi commands to configure, monitor, and manage Isilon clusters and the individual nodes in a cluster. Brief descriptions, usage information, and examples are provided for each command. Square brackets indicate an optional element. If you omit the contents of the square brackets when specifying a command, the command still runs successfully.

Angle brackets indicate a placeholder value. You must replace the contents of the angle brackets with a valid value, otherwise the command fails.

emc cli commands

Braces indicate a group of elements. If the contents of the braces are separated by a vertical bar, the contents are mutually exclusive. If the contents of the braces are not separated by a bar, the contents must be specified together.

Ellipses indicate that the preceding element can be repeated more than once. If ellipses follow a brace or bracket, the contents of the braces or brackets can be repeated more than once. Each isi command is broken into three parts: command, required options, and optional options. Required options are positional, meaning that you must specify them in the order that they appear in the syntax diagram.

However, you can specify a required option in an alternative order by preceding the text displayed in angle brackets with a double dash. For example, consider isi snapshot snapshots create.Recently I got a task to run a command or script to delete files in a given folder after a success backup.

In general, there are two major ways, one way is to use PowerShell script and include Networker backup command, and the other way is to use EMC Networker customized backup command.

I chose to use the second way because it is more closely integrated with Networker and easier to manage and monitor. There are some requirements listed in Networker Administrator Guide, I just listed some key ones as below:. Below is the script I used by modifying the EMC example with below three steps:. You are commenting using your WordPress.

emc cli commands

You are commenting using your Google account. You are commenting using your Twitter account. You are commenting using your Facebook account. Notify me of new comments via email. Notify me of new posts via email. I follow the steps as below: Step 1: In the client host, create a file save Step 2: Use txt editor to edit the Save There are some requirements listed in Networker Administrator Guide, I just listed some key ones as below: The program name must begin with either the prefix save or nsr and must not exceed 64 characters.

The program must reside on the client in the same directory as the NetWorker save command. Always specify the full path of the save command in the script.

Swiggy partner api

The NetWorker save command must be used in the backup program. All commands within the program file must complete successfully.

10g vs 5g

Otherwise, the NetWorker server cannot complete the remaining instructions. Share this: Twitter Facebook.

A Simple Example of EMC Networker Customized Backup Command

Like this: Like Loading Leave a Reply Cancel reply Enter your comment here Fill in your details below or click an icon to log in:. Email required Address never made public.

Punjabi whatsapp group link 2019

Name required.In this article, let us discuss how to use powermt command with practical examples. This is the most frequently used powermt command, which will display all the attached logical devices to the server.

emc cli commands

This is similar to 1, but displays whether hba is enabled or not, as shown in the last column of the output. You can change the mode of a specific HBA to either standby or active using this command. If a previously dead path is alive, it will be marked as alive, and if a previously alive path is dead, it will be marked as dead. For some reason, if you see the default owner and the current owner of a particular LUN is not the same storage processor, then execute the following command, which will make the current owner of the LUN same as the default owner.

Instead of dev, you can also specify class in the powermt restore command. Class can be one of the following depending on your system. If you are changing the PowerPath configurations for testing purpose, you can save the current configuration using powermt save command.

Kuma games facebook

Following is the partial content of this file. When you are testing EMC PowerPath configuration, if you are not satisfied with the new configuration, you can go back to the previous configuration. For example, to restore the configuration to a specific file that you created in the above powermt save example, do the following. How are you doing? I had been following your articles some months before when i was only working on Linux and left following your articles quite some time.

But guess what now i am into storage and when i searched for powerpath, i have been brought to your website again for Storage???? It was really helpful keep the good work up and running. If i have a specific question abt. Is there anyway we can have the servername printed on the same level of powermt command? Ramesh, We were working on a migration needing to track the errors being shown using the powermt config command.

As we resolved the cabling issue, is there a way to reset the error counts that are shown from the powermt config output? Excellent, I have question, how to clear the historic errors. Is there any command to clear?

Custom wood 1911 grips for sale

Awesome list. I love powerpath. I had to debug an issue with little to no help from the customer they owned everything outside of the server and would not let me see anything on the switch.

I knew there was a bad cable but they made me prove it and EMC powerpath was definitely helpful. One command to add for AIX users.You can use it for storage provisioning and manage array configurations from any one of the managed storage system on the LAN. It can also be used to automate the management functions through shell scripts and batch files. CLI commands for many functions are server based and are provided with the host agent.

The remaining CLI commands are web-based and are provided with the software that runs in storage system service processors SPs. In this example-h Specifies the IP address or network name of the targeted SP on the desired storage system. The default, if you omit this switch, is localhost.

EMC ECS CLI Command Reference

You can create more RAID groups 1, 2 and so on using the below commands:. This is similar to how you create raid group from the navsiphere GUI.

In the following example, hlu is the host LUN number. This is the number that host will see from its end. Alu is the array LUN number, which storage system will see from its end.

Register the host as shown below by specificing the name of the host. In this example, the host server is elserver1. Finally, connect the host to the storage group as shown below by using -connecthost option as shown below.

You should also specify the storagegroup name appropriately. Once you complete the above steps, your hosts should be able to see the newly provisioned storage.

To extend a RAID group with new set of disks, you can use the command as shown in the below example. This is similar to how you destroy raid group from the navisphere GUI. The naviseccli command initiates the copying of data from a failing disk to an existing hot spare while the original disk is still functioning. Once the copy is made, the failing disk will be faulted and the hotspare will be activated. When the faulted disk is replaced, the replacement will be copied back from the hot spare.This section contains general CLI commands, including commands relating to licenses, certificates, login banner, and syslog.

Acknowledgment can be performed at Storage Pool level or at device level, and for counter type. Extract the MDM root certificate to the specified file.

This is the first step in the process of exchanging certificates between replication peer systems. Reset the specified oscillating failure counters to zero. This command is useful when you have fixed a problem and want to ensure that an alert is no longer active in the system. Set the login banner that is displayed at every login to the system, or remove an existing login banner.

Modify oscillating failure counter parameters. You can use this command to configure the time interval associated with each window type and the number of failures allowed before reporting commences for each window type, per counter. Configure the PowerFlex system to restrict access from remote clients to read-only operations on the MDM.

15 EMC PowerPath Powermt Command Examples – Display, Check, Remove, Config, Restore

When this restriction is enabled, remote client users cannot change any configurations on the MDM. However, users on a local host may still make configuration changes while the restriction is enforced.EMC Global Services.

Cloud Tiering Appliance. Data Protection Advisor. Infrastructure Connectivity. Create interfaces to enable and control access between the system, the network, and configured hosts. Specify the IP address for the interface as well as the IP addresses for the subnet mask and gateway. The following command creates a replication interface. Configure remote storage systems that connect to the system to which you are logged in. The system uses the configuration to access and communicate with the remote system.

For example, to use remote replication, create a configuration that specifies the remote system to use as the destination for the replication session.

emc cli commands

View the configuration for a remote system on the local system. You can filter on the configuration ID of the remote system. Verify the configuration settings for a remote system to ensure that the source storage resource can connect to the remote storage resource. Storage replication is a process in which storage data is duplicated either locally or to a remote network device. Replication produces a read-only, point-in-time copy of source storage data and periodically updates the copy, keeping it consistent with the source data.

Storage replication provides an enhanced level of redundancy in case the main storage backup system fails. As a result:. Each replication session is identified by an ID. The Unisphere online help provides more details about storage replication.

Delete a replication session. You can then connect a host to either storage resource. Run this command on the destination system to perform a failover of a replication session, with possible data loss, in response to an emergency scenario in which the source becomes unavailable.

To reestablish communication between the source and destination, fail back the session that has failed over. Fail back replication sessions explains how to fail back a replication session that has failed over. To initiate a planned downtime, run this command on the source system by specifying the -sync option with the value yes. When you fail over a replication session from the source system, the destination system is fully synchronized with the source to ensure that there is no data loss.

The destination storage resource can be used for providing access to the host. Fail back a replication session that has failed over.


comments